Huntron

Internal Huntron Tracker Technology
 
Some models of IFD™ TE has a built-in Huntron Tracker provided under licence by Huntron Inc.
 
Picture of Huntron Tracker 2800, the OEM instrumentation board is fitted internal in the VIFD™
 
Specifications:
Number of Voltages plus values
24 voltages: 200mV, 400mV, 600mV, 800mV, 1V to 20V in 1V steps including 10V (Low), 15V (Med 1), 20V (Med 2)
Number of Resistances plus values
16 resistances: 10Ω, 20Ω, 50Ω, 100Ω, 200Ω, 500Ω, 1kΩ, 2kΩ, 5kΩ, 10kΩ, 20kΩ, 50kΩ, 100kΩ, 54Ω (Low)*, 1.2kΩ (Med 1)*, 26.7kΩ (Med 2)*
Number of Frequencies plus values
40 frequencies: 20Hz to 190Hz in 10Hz steps; 200Hz to 1.9kHz in 100Hz steps; 2kHz to 5kHz in 1kHz steps
    
For more information on incorporating this instrumentation in to your IFD™ TE, then contact your Authorised Distribution.
 
To avoid possible damage to the IFD™ TE
or the equipment under test, follow these guidelines:
 
·     Do not use this equipment on any “powered” circuits.   The IFD™ TE supplies the entire electronic testing stimulus needed.   Failure to do so could damage the equipment and void the factory warranty.
 
·     Do not connect the IFD™ TE system to any additional test equipment that produces stimulated High Voltages or Currents that might damage the IFD™ hardware, and this will include insulation tests and it may include some Diode testing; if unsure then contact your Distributor for more information before proceeding.
 