Power Supply Information

 
Ø     VIFD™
 
  • AC Power Input:
  • Input Voltage (nom) 100-240VAC
  • Input Voltage (limits) 90-264VAC
  • Maximum Input Current 2.75Arms
  • Input Frequency (nom) 50/60Hz
  • Input Frequency (limits) 47/63Hz
  • Input current limit by slow-blow 5A input fuses (must be changed by OEM if blown)
 
  • DC Power Input:
  • Ideal Input Operating voltage 12-24V
  • Minimum Input Operating voltage 9V (not recommended)
  • Maximum input Operating voltage 28V (hard clamping will occur at 34V)
  • Maximum Input Ripple <1%
  • Input current limit (fuse protected) 25A (must be changed by OEM if blown)
 
  • Maximum Power: 250 Watts / 300 Watts peak
 
Ø     Portable Unit (Ncompass™ 4000  Series)
 
  • Power Supply: 90/132 or 175/264VAC Auto Switching
  • Power Line Frequency: 47-63Hz
  • Power Usage: 28W (Approx.)
  • Maximum Output at Test Point terminals: 3.2Vdc at 1.06mA
 
Ø     IDFIS™
 
  • Power Supply: 90/132 or 175/264VAC Auto Switching UPS
  • Power-up incremental power-on for multiple Pods
  • Power Line Frequency: 47-63Hz
  • Power Usage:  Subject to number of modules installed - consult your Distributor
  • Maximum Output at Test Point terminals: 3.2Vdc at 1.06mA
 
Controlling Computer
 
  • Power Supply: 100-240VAC
  • Power Line Frequency: 47-63Hz
  • Power Usage: 152W (approx depending on model)
  • Maximum Output at motherboard/HDD: 12Vdc
 
Detachable Power Cord
 
  • VAC detachable power cord is rated at 240V 10Amp with a F3A250V fuse in the mains plug where applicable.  No modifications, repairs or replacement of the cord are to be carried out that would adversely effect the safety or lower the rating, thus making the cord inadequate for safe operation.
 
  • VDC detachable power cord is rated at 100V 25Amp.  No modifications, repairs or replacement of the cord are to be carried out that would adversely effect the safety or lower the rating, thus making the cord inadequate for safe operation.
 
 
The IFD™ TE, the CC, and any peripheral equipment should be connected where possible to the mains supply by means of an approved surge suppression device to prevent electronic damage and surge protection.  Do not connect or disconnect the IFD™ TE without undertaking the correct Powering Down sequence.
 
 
 
Any electrical installation, repair or maintenance activity on the any of the IFD™ TE must be carried out by an appropriately qualified Electrician.
If you are unsure, or experience an issue with the IFD™ TE of an electrical nature, please contact your Authorised Distributor for advice.
 
 
 
 
Parts of the IFD™ TE contains miniature ‘button’ batteries as part of the motherboard and some interface cards and in some cases it may contain a larger rechargeable battery pack if in laptop format and the Copernicus Technology Ltd Break-out-Box contains a 9V Alkaline battery. 
These batteries contain heavy metals and must be recycled/disposed of correctly and NOT disposed of along with normal household waste. 
If additional information on disposal is required, please check with your local authority for full guidelines.