There are two other applications for the BoB MKII as follows:
1. It can be used to connect and use other test equipment to the UUT by using the same IA made for the Ncompass™ Analyzer. For example, the Ncompass™ Analyzer would be used to detect the TPs that exhibit intermittent faults. Once that had been established, the BoB MKII can then be used to connect a TDR or SSTDR to the UUT to further narrow down the root cause of the fault.
Using these methods assumes that the faults is a slow transiting or hard fault, as fast intermittent faults are extremely hard to detect using these techniques.
2. It can be used to connect directly to the Ncompass™ Analyzer for carrying out calibration or performance tests of the Analyzer. This should only be carried out by the Authorised Distributor or by a qualified technician authorised to do so by the Distributor.