Input current limit by slow-blow 5A input fuses (must be changed by OEM if blown)
DC Power Input:
Ideal Input Operating voltage 12-24V
Minimum Input Operating voltage 9V (not recommended)
Maximum input Operating voltage 28V (hard clamping will occur at 34V)
Maximum Input Ripple <1%
Input current limit (fuse protected) 25A (must be changed by OEM if blown)
Maximum Power: 250 Watts / 300 Watts peak
ØPortable Unit (Ncompass™ 4000 Series)
Power Supply: 90/132 or 175/264VAC Auto Switching
Power Line Frequency: 47-63Hz
Power Usage: 28W (Approx.)
Maximum Output at Test Point terminals: 3.2Vdc at 1.06mA
ØIDFIS™
Power Supply: 90/132 or 175/264VAC Auto Switching UPS
Power-up incremental power-on for multiple Pods
Power Line Frequency: 47-63Hz
Power Usage: Subject to number of modules installed - consult your Distributor
Maximum Output at Test Point terminals: 3.2Vdc at 1.06mA
Controlling Computer
Power Supply: 100-240VAC
Power Line Frequency: 47-63Hz
Power Usage: 152W (approx depending on model)
Maximum Output at motherboard/HDD: 12Vdc
Detachable Power Cord
VAC detachable power cord is rated at 240V 10Amp with a F3A250V fuse in the mains plug where applicable. No modifications, repairs or replacement of the cord are to be carried out that would adversely effect the safety or lower the rating, thus making the cord inadequate for safe operation.
VDC detachable power cord is rated at 100V 25Amp. No modifications, repairs or replacement of the cord are to be carried out that would adversely effect the safety or lower the rating, thus making the cord inadequate for safe operation.
The IFD™ TE, the CC, and any peripheral equipment should be connected where possible to the mains supply by means of an approved surge suppression device to prevent electronic damage and surge protection. Do not connect or disconnect the IFD™ TE without undertaking the correct Powering Down sequence.
Any electrical installation, repair or maintenance activity on the any of the IFD™ TE must be carried out by an appropriately qualified Electrician.
If you are unsure, or experience an issue with the IFD™ TE of an electrical nature, please contact your Authorised Distributor for advice.
Parts of the IFD™ TE contains miniature ‘button’ batteries as part of the motherboard and some interface cards and in some cases it may contain a larger rechargeable battery pack if in laptop format and the Copernicus Technology Ltd Break-out-Box contains a 9V Alkaline battery.
These batteries contain heavy metals and must be recycled/disposed of correctly and NOT disposed of along with normal household waste.
If additional information on disposal is required, please check with your local authority for full guidelines.